WHEN YOUR LINE GETS BUSY.

Loaded Latency & Bufferbloat Check

See how HTTP response times change during test traffic, with sample counts and clear limits.

Ready to check your connection
Download
—Mbps
Upload
—Mbps
HTTP ping
—ms
Jitter
—ms

Free to use. No account. Just answers.

Inspect the evidence and limits

Compare idle and loaded response times

Inspect HTTP timing under this test’s bounded traffic. Missing or sparse probes stay visible; no bufferbloat grade is assigned.

Cloudflare · automatic routingHow we measure

Uses up to 96 MB of test payload, plus overhead. Cloudflare receives your IP address. Privacy details

Ready to check your connection

Compare responsiveness, not just capacity

Bufferbloat describes excessive queueing delay. A connection can move a large amount of data while small interactive requests wait behind competing traffic. Looking at idle and loaded response times can reveal a pattern worth investigating when a call or game becomes delayed during transfers.

This page is a bounded loaded-latency check. It uses the same throughput engine as the general test, but presents the idle and loaded evidence directly. Its short single-request transfers do not guarantee sustained saturation of a fast connection, so it does not assign an authoritative bufferbloat grade.

Read the sample counts before the differences

The engine collects ten idle HTTP samples, then attempts timing probes during download and upload phases. The table displays each phase’s median and the number of completed probes. A descriptive difference is shown only when at least three loaded probes complete.

Three probes are a display safeguard, not a validated confidence threshold. An unavailable or sparse phase cannot support a conclusion that the connection has no bufferbloat. Negative differences are retained because normal timing variation can make a loaded median lower than the idle observation.

Create a controlled comparison

Use Ethernet where practical and pause unrelated transfers for the baseline. Keep the device, profile, browser and VPN conditions consistent. Standard allows more payload than Data saver, but neither setting guarantees saturation.

Repeat around the symptom you observe in a real workload. If delay reliably rises during a backup and falls when it pauses, investigate contention. If the symptom appears with no traffic, baseline routing, wireless conditions, device scheduling or the application may also be involved.

Understand the measurement limits

The timing includes browser and endpoint overhead. HTTP probes can interact with browser connection scheduling. A remote bottleneck, Wi-Fi contention or a VPN can affect the observations as well as a router queue. This page cannot identify where queueing occurs.

When queue-management decisions depend on the answer, use a documented sustained-load method such as those listed by the Bufferbloat project, along with suitable hardware. A richer chart or a letter grade would not make this short test equivalent to those methods.

Make changes that you can evaluate

Some routers support active or smart queue management. Consult the documentation for the exact model and firmware, preserve the original settings and avoid guessing shaping rates from one brief run. Incorrect settings can unnecessarily reduce throughput.

Application upload limits and scheduling backups can also help manage competing demand. After each controlled change, repeat a comparable measurement and the real application. Look for a repeatable improvement rather than treating a single number as a diagnosis.

Sources & further reading

Our explanations distinguish the browser measurement from the underlying connection. These primary references provide context; they do not endorse this site.

Bufferbloat project: Tests for bufferbloat

Tools and procedures for observing latency while a connection carries load, including sustained-load alternatives.

Our measurement method and limits

The implemented request sequence, calculations and payload budgets.

MDN: PerformanceResourceTiming

Browser resource timing and its relationship to network requests.

A FEW GOOD QUESTIONS

Let’s clear things up.

Does a small difference prove there is no bufferbloat?

No. The workload may not saturate the connection, and short sampling can miss a problem.

Why is no difference shown for a phase?

There may be fewer than three completed loaded probes, or a required timing value may be unavailable. No grade is inferred from missing evidence.

A CLEARER CONNECTION STARTS HERE

Ready to take out the guesswork?

Check your connection